Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:11 AM
Ignite Modification Date: 2025-12-25 @ 2:11 AM
NCT ID: NCT03382860
Brief Summary: The purpose of this pilot study is to assess whether the intracranial pressure (ICP) can be detected by using a non-invasive retinal fundus scanner, recording the vessels of the eye entering from the optic disc. The artery's diameter (A) is measured and compared to the vein's diameter (V) thereby a ratio A/V can be calculated. This ratio is compared to the values obtained from conventional fiberoptic intraparenchymal, intraventricular ICP monitoring using external ventricular drain (EVD) or lumbar pressure monitoring. Valid non-invasive techniques for objective measurements of the intracranial pressure do not exist at the given time now and this study could prove to help the development of monitoring patients ICP without surgical intervention.
Detailed Description: Intracranial pressure (ICP) is based on the simple principle of Monroe-Kellie Doctrine. Since the volume of the cranial cavity is constant and the brain, CSF and blood can only compensate for a certain change in volume, pressure will increase at a critical increase in volume. An increase in pressure caused by an increase in intracranial volume is distributed throughout the entire brain and spinal canal equally. The normal range of ICP varies with age. Normal values are less than 10-15 mmHg for adults and adolescents, 3-7 mmHg for younger children and 1.5-6 mmHg for newborns even sub-atmospheric ICP has been shown. The threshold for intracranial hypertension varies in the literature, which is reflected in the clinical use. Generally, ICP above 20 mmHg is defined intracranial hypertension. ICP higher than 20-25 may require treatment, and continuous ICP above 40 mmHg indicates severe, lethal intracranial hypertension. Some forms of measurements, e.g. 1. Intraparenchymal strain gauge or fiber optics or 2. Intraventricular ICP monitoring via external ventricular drain (EVD). EVD is considered golden standard, but in the daily clinic there is often no or limited difference between 1. and 2. The issue regarding invasive methods are the same as for any surgical procedure, e.g. bleeding and infection. Risk of bleeding is 2-10% for EVD and 2.5% for intraparenchymal monitors. The consequences of such a bleed can be severe and result in disability. EVD has a higher risk of infection (5-20%) compared to intraparenchymal monitors (0-0.1%). Non-invasive methods such as transcranial doppler ultrasound pulsation index and optic nerve sheath diameter has been used in studies, which seemed promising, but has not yet been validated for routine clinical use. Also, in non-invasive methods there are significant inter observational variation. Studies of the eye's fundus have shown a correlation between ICP and ratio between artery and vein diameter (A/V ratio, unpublished data) Currently, there are no published work that has considered the correlation between A/V ratio and ICP, however there is a study with a theoretical prediction of such a correlation (Babbs CF 2016. Weldon School of Biomedical Engineering Faculty Working Papers. Paper 1 http://docs.lib.purdue.edu/bmewp/1). This study investigates the correlation between non-invasive fundus ICP estimation and intracranial pressure monitoring. In practice, all conscious and able adults admitted to Odense University Hospital for intracranial pressure monitoring/measurements by either an EVD, intraparenchymal ICP monitor or lumbar spinal fluid pressure assessment are enrolled.
Study: NCT03382860
Study Brief:
Protocol Section: NCT03382860