The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 2:08 AM
Ignite Modification Date: 2025-12-25 @ 2:08 AM
NCT ID: NCT00853060
Brief Summary: During weaning from mechanical ventilation process, the energy expenditure in T tube is greater than pressure support ventilation.
Detailed Description: The energy expenditure (EE) was measured during the two periods of 30-minutes, with the 10 first minutes being discarded for analysis purposes. The other variables were recorded and monitored during the 10th and the 30th minute, in both pressure support (PS) and t-Tube (TT) modes. Patients were randomized in terms of sequence selection: PS - TT or TT - PS. In the baseline period, patients were receiving mechanical ventilation (Servo 900C and Servo 300; Siemens-Elema, Solna, Sweden), with PS ranging from 10 to 15cmH2O. During the PS mode, patients received assisted pressure ventilation of 10 cmH2O, 5 cmH2O of final positive expiratory pressure, the sensitivity of -1cmH2O and FiO2 of 0.4. During TT mode, oxygen flow was delivered in order to keep the same FiO2 that was provided in PS (0.4) as controlled by monitor screen (Datex Ohmeda S/5 - Compact Airway Module, M-COVX model, Finland). In this mode, an extensor was employed, one end of which was connected to the oxygen-enriched and the other end was secured to a 3-output ("T") connector, which was attached to the patient's ventilatory prosthesis. During the rest period (30 minutes), patients returned to the mechanical ventilation parameters utilized in the baseline period.
Study: NCT00853060
Study Brief:
Protocol Section: NCT00853060