Description Module

Description Module

The Description Module contains narrative descriptions of the clinical trial, including a brief summary and detailed description. These descriptions provide important information about the study's purpose, methodology, and key details in language accessible to both researchers and the general public.

Description Module path is as follows:

Study -> Protocol Section -> Description Module

Description Module


Ignite Creation Date: 2025-12-25 @ 1:27 AM
Ignite Modification Date: 2025-12-25 @ 1:27 AM
NCT ID: NCT04199793
Brief Summary: Left ventricular assist device (LVAD) patients remain at risk for pump thrombus and thromboembolic events through multiple mechanisms. The HeartWare® Ventricular Assist System (HVAD®, HeartWare Inc., Framingham, MA, USA) includes a novel speed modulation feature called Lavare™ cycle. The Lavare™ Cycle is aimed to promote washing of left ventricle to decrease blood stasis and subsequent risk of thrombus formation, ingestion and/or expulsion. No prior study has prospectively evaluated the impact of Lavare™ cycle on patient outcomes in a randomized fashion. We intend to assess effects of Lavare™ Cycle among patients receiving HVAD LVAD in this randomized controlled pilot project.
Detailed Description: Left ventricular assist device (LVAD) patients remain at risk for pump thrombus and thromboembolic events through multiple mechanisms. The HeartWare® Ventricular Assist System (HVAD®, HeartWare Inc., Framingham, MA, USA) includes a novel speed modulation feature called Lavare™ cycle. It consists of 3 phases: phase 1 - a 200 rpm decrease from baseline speed for 2 seconds, phase 2 - a 100 rpm increase from baseline for 1 second and phase 3 - return of speed to baseline; this cycle repeats itself once every minute. The LavareTM Cycle is aimed to promote washing of left ventricle to decrease blood stasis and subsequent risk of thrombus formation, ingestion and/or expulsion. In a post-hoc analysis of ReVOLVE registry, which includes 248 patients implanted with the HVAD following Conformité Européenne Mark in nine centers in Europe and Australia, no adverse impact on survival was observed with Lavare™ cycle. Additionally, lower risk of stroke, sepsis and right heart failure was observed among those with Lavare™ cycle in the above-mentioned study. However, no prior study has prospectively evaluated the impact of Lavare™ cycle on patient outcomes in a randomized fashion. In this prospective randomized controlled trial, we intend to assess the role of Lavare™ cycle in pump related complications.
Study: NCT04199793
Study Brief:
Protocol Section: NCT04199793