Adverse Events Module

Adverse Events Module

For researchers submitting trial data to ClinicalTrials.gov, the Adverse Events module is one of four mandatory results sections. It requires reporting in three primary categories: All-Cause Mortality: A table tracking all deaths that occurred during the study, regardless of cause. Serious Adverse Events (SAEs): A tabular summary of events resulting in death, life-threatening conditions, hospitalization, or significant disability. Other Adverse Events: A table for non-serious events that exceed a specific frequency threshold, such as 5% within any study arm.

Adverse Events Module path is as follows:

Study -> Results Section -> Adverse Events Module -> Event Groups

Study -> Results Section -> Adverse Events Module -> Serious Events

Study -> Results Section -> Adverse Events Module -> Other Events

Adverse Events Module


Ignite Creation Date: 2025-12-24 @ 5:49 PM
Ignite Modification Date: 2025-12-25 @ 3:15 PM
NCT ID: NCT00927368
Description: None
Frequency Threshold: 0
Time Frame: None
Study: NCT00927368
Study Brief: Comparison of 3 Techniques for Ultrasound-guided Femoral Nerve Catheter Insertion
Event Groups(If Any):

Event Groups

Title Description Deaths # Affected Deaths # At Risk Serious # Affected Serious # At Risk Other # Affected Other # At Risk View
Ultrasound Guidance Alone The Tuohy needle was inserted in out-plane approach. Needle placement was considered adequate when the tip was visualized beneath the fascia iliaca; the catheter was then introduced 5 cm beyond the needle tip. Electrical stimulation was not used. ultrasound guidance alone: The Tuohy needle was inserted in out-plane approach. Needle placement was considered adequate when the tip was visualized beneath the fascia iliaca; the catheter was then introduced 5 cm beyond the needle tip. Electrical stimulation was not used. None None 0 147 0 147 View
Ultrasound Guidance Needle Stimulation For the ultrasound guidance and needle stimulation arm, the Tuohy needle was positioned with the tip beneath the fascia iliaca under ultrasound guidance. The needle tip was then adjusted as necessary to obtain a quadriceps muscle response with a stimulating current ≤0.5 mA (2 Hz, pulse width 0.1 msec). Subsequently, the catheter was threaded 5 cm beyond the needle tip without additional electrical stimulation ultrasound guidance and needle stimulation: For the ultrasound guidance and needle stimulation group, the Tuohy needle was positioned with the tip beneath the fascia iliaca under ultrasound guidance. The needle tip was then adjusted as necessary to obtain a quadriceps muscle response with a stimulating current ≤0.5 mA (2 Hz, pulse width 0.1 msec). Subsequently, the catheter was threaded 5 cm beyond the needle tip without additional electrical stimulation. None None 0 152 0 152 View
Ultrasound Guidance+Catheter Stimulation For the ultrasound guidance and catheter stimulation group, the Tuohy needle was positioned with the tip beneath the fascia iliaca under ultrasound guidance. The needle tip was then adjusted as necessary to obtain a quadriceps muscle response with a stimulating current ≤0.5 mA. At that point, the peripheral nerve stimulator was then disconnected from the stimulating needle and connected to the proximal end of the catheter. The catheter was then advanced 5 cm past the needle tip. If the motor response disappeared during catheter advancement, the catheter was withdrawn slightly until the response returned. Needle orientation and catheter advancement were adjusted as necessary to elicit quadriceps contractions via the catheter with a stimulating current ≤0.5 mA. None None 0 138 0 138 View
Serious Events(If Any):
Other Events(If Any):