For researchers submitting trial data to ClinicalTrials.gov, the Adverse Events module is one of four mandatory results sections. It requires reporting in three primary categories: All-Cause Mortality: A table tracking all deaths that occurred during the study, regardless of cause. Serious Adverse Events (SAEs): A tabular summary of events resulting in death, life-threatening conditions, hospitalization, or significant disability. Other Adverse Events: A table for non-serious events that exceed a specific frequency threshold, such as 5% within any study arm.
Adverse Events Module path is as follows:
Study -> Results Section -> Adverse Events Module -> Event Groups
Study -> Results Section -> Adverse Events Module -> Serious Events
Study -> Results Section -> Adverse Events Module -> Other Events
| Title | Description | Deaths # Affected | Deaths # At Risk | Serious # Affected | Serious # At Risk | Other # Affected | Other # At Risk | View |
|---|---|---|---|---|---|---|---|---|
| AV400 | The nurse will use the Accuvein AV400 to assist with intravenous access. If the nurse cannot place the catheter after 2 tries (two needle sticks into the skin) then the nurse will attempt to put in the catheter without using the device. While the nurse is putting in the catheter, a member of the study team will record the number of tries, the type of catheter and where the catheter is successfully put in. Afterwards the parent and nurse will be surveyed on their satisfaction and the nurse will be asked specific questions about using the AV400. Accuvein AV400: This device is FDA approved for assistance with intravenous access. It has been shown to cause no harm to patients. The device utilizes infrared technology to provide a visible map of the subject's blood vessels where the light is shone. | 0 | None | 0 | 11 | 0 | 11 | View |
| Standard | The nurse will use the standard technique for intravenous access (not using the Accuvein AV400). If the nurse cannot place the catheter after 2 tries (two needle sticks into the skin) then the nurse will attempt to put in the catheter with the help of the Accuvein AV400. While the nurse is putting in the catheter, a member of the study team will record the number of tries, the type of catheter and where the catheter is successfully put in. Afterwards the parent and nurse will be surveyed on their satisfaction and the nurse will be asked specific questions about using the AV400 if they crossed over to the AV400 after two failures. | 0 | None | 0 | 12 | 0 | 12 | View |