Adverse Events Module

Adverse Events Module

For researchers submitting trial data to ClinicalTrials.gov, the Adverse Events module is one of four mandatory results sections. It requires reporting in three primary categories: All-Cause Mortality: A table tracking all deaths that occurred during the study, regardless of cause. Serious Adverse Events (SAEs): A tabular summary of events resulting in death, life-threatening conditions, hospitalization, or significant disability. Other Adverse Events: A table for non-serious events that exceed a specific frequency threshold, such as 5% within any study arm.

Adverse Events Module path is as follows:

Study -> Results Section -> Adverse Events Module -> Event Groups

Study -> Results Section -> Adverse Events Module -> Serious Events

Study -> Results Section -> Adverse Events Module -> Other Events

Adverse Events Module


Ignite Creation Date: 2025-12-25 @ 1:22 AM
Ignite Modification Date: 2025-12-25 @ 11:31 PM
NCT ID: NCT02802293
Description: None
Frequency Threshold: 0
Time Frame: 8 weeks
Study: NCT02802293
Study Brief: Treatment of Depression With Connectivity Guided Robotically Delivered rTMS
Event Groups(If Any):

Event Groups

Title Description Deaths # Affected Deaths # At Risk Serious # Affected Serious # At Risk Other # Affected Other # At Risk View
Standard rTMS Aiming Active repetitive transcranial magnetic stimulation (rTMS) will be delivered to the left DLPFC using the standard aiming strategy with the rTMS coil positioned using a robotic arm. In this arm, rTMS will be delivered at 10 Hz in 4 sec trains with 26 sec inter-train intervals, 37.5 minutes/session (i.e. 3,000 pulses/session), 5 sessions/week, for 4 weeks. repetitive transcranial magnetic stimulation: The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver repetitive electromagnetic pulses in this research study's treatment of major depressive disorder. robotic arm: This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting. 0 None 0 1 1 1 View
Anterior DLPFC Targeting Active rTMS will be delivered to the left anterior DLPFC using connectivity-based, image-guided aiming with the rTMS coil positioned using a robotic arm. In this arm, rTMS will be delivered at 10 Hz in 4 sec trains with 26 sec inter-train intervals, 37.5 minutes/session (i.e. 3,000 pulses/session), 5 sessions/week, for 4 weeks. repetitive transcranial magnetic stimulation: The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver repetitive electromagnetic pulses in this research study's treatment of major depressive disorder. robotic arm: This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting. 0 None 0 2 1 2 View
Posterior DLPFC Targeting Active rTMS will be delivered to the left posterior DLPFC using connectivity-based, image-guided aiming with the rTMS coil positioned using a robotic arm. In this arm, rTMS will be delivered at 10 Hz in 4 sec trains with 26 sec inter-train intervals, 37.5 minutes/session (i.e. 3,000 pulses/session), 5 sessions/week, for 4 weeks. repetitive transcranial magnetic stimulation: The MagPro R30 is an advanced, high performance magnetic stimulator designed primarily for non-invasive clinical use. The non-invasive brain stimulation system will be used to deliver repetitive electromagnetic pulses in this research study's treatment of major depressive disorder. robotic arm: This robotic system is based on a commercially available neurosurgical robot. The robot is mounted on a mobile (i.e. retractable wheels) cart which holds the robot controller and the TMS power supply and pulse-generation computer. The robotic system will be used for TMS coil positioning/targeting. 0 None 0 3 1 3 View
Serious Events(If Any):
Other Events(If Any):

Other Events

Term Type Organ System Vocab View
Headache SYSTEMATIC_ASSESSMENT General disorders None View