Adverse Events Module

Adverse Events Module

For researchers submitting trial data to ClinicalTrials.gov, the Adverse Events module is one of four mandatory results sections. It requires reporting in three primary categories: All-Cause Mortality: A table tracking all deaths that occurred during the study, regardless of cause. Serious Adverse Events (SAEs): A tabular summary of events resulting in death, life-threatening conditions, hospitalization, or significant disability. Other Adverse Events: A table for non-serious events that exceed a specific frequency threshold, such as 5% within any study arm.

Adverse Events Module path is as follows:

Study -> Results Section -> Adverse Events Module -> Event Groups

Study -> Results Section -> Adverse Events Module -> Serious Events

Study -> Results Section -> Adverse Events Module -> Other Events

Adverse Events Module


Ignite Creation Date: 2025-12-25 @ 12:43 AM
Ignite Modification Date: 2025-12-25 @ 10:55 PM
NCT ID: NCT02163967
Description: Of the 21 subjects enrolled, 20 participated in the sham stimulation session, 19 participated in the low dose stimulation session and 18 participated in the high dose stimulation session.
Frequency Threshold: 5
Time Frame: 1 hour
Study: NCT02163967
Study Brief: Effect of CES on Parasympathetic Tone
Event Groups(If Any):

Event Groups

Title Description Deaths # Affected Deaths # At Risk Serious # Affected Serious # At Risk Other # Affected Other # At Risk View
Sham Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100) sham stimulation for 20 minutes, once Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100): low voltage alternating current transcranial electrical stimulation 0 None 0 20 1 20 View
Low Dose Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100) 1mAmp stimulation for 20 mintues, once Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100): low voltage alternating current transcranial electrical stimulation 0 None 0 19 11 19 View
High Dose Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100) 2mAmp stimulation for 20 minutes, once Cranial Electrical Stimulation Fisher-Wallace Stimulator (Model FW100): low voltage alternating current transcranial electrical stimulation 0 None 0 18 12 18 View
Serious Events(If Any):
Other Events(If Any):

Other Events

Term Type Organ System Vocab View
light flickering NON_SYSTEMATIC_ASSESSMENT Nervous system disorders None View
itching or tingling of scalp NON_SYSTEMATIC_ASSESSMENT Nervous system disorders None View