Adverse Events Module

Adverse Events Module

For researchers submitting trial data to ClinicalTrials.gov, the Adverse Events module is one of four mandatory results sections. It requires reporting in three primary categories: All-Cause Mortality: A table tracking all deaths that occurred during the study, regardless of cause. Serious Adverse Events (SAEs): A tabular summary of events resulting in death, life-threatening conditions, hospitalization, or significant disability. Other Adverse Events: A table for non-serious events that exceed a specific frequency threshold, such as 5% within any study arm.

Adverse Events Module path is as follows:

Study -> Results Section -> Adverse Events Module -> Event Groups

Study -> Results Section -> Adverse Events Module -> Serious Events

Study -> Results Section -> Adverse Events Module -> Other Events

Adverse Events Module


Ignite Creation Date: 2025-12-25 @ 12:14 AM
Ignite Modification Date: 2025-12-25 @ 10:16 PM
NCT ID: NCT02299258
Description: None
Frequency Threshold: 0
Time Frame: None
Study: NCT02299258
Study Brief: Gastric Outlet Obstructions Tailored Covered Stents for GOO
Event Groups(If Any):

Event Groups

Title Description Deaths # Affected Deaths # At Risk Serious # Affected Serious # At Risk Other # Affected Other # At Risk View
Standard Stents MTN-CG-s-20/100 Standard uncovered stents were used in the control group. The ends of the stents were semi-spherical with diameters of 28 mm and length of 20 mm. The length of the stents was 100 mm Standard stents MTN-CG-s-20/100: The ends of the stents were semi-spherical with diameters of 28 mm and length of 20 mm. The length of the stents was 100 mm None None 4 31 0 31 View
Tailored Stents MTN-WE-20/100-A The distal portion of the GOO tailored stents was semi-spherical, with a length of 20 mm, and a diameter of 28 mm. The middle segment had a diameter of 20 mm. The overall length of the stents was 100 mm. Both the middle part and the bottom of the proximal cup segment, and a part of the proximal funnel segment, were covered by a polyethylene membrane. Tailored stents MTN-WE-20/100-A: cup-shaped or funnel-shaped, according to the shapes of the proximal GOOs. None None 25 32 0 32 View
Serious Events(If Any):

Serious Events

Term Type Organ System Vocab View
Bleeding SYSTEMATIC_ASSESSMENT Blood and lymphatic system disorders GOOSS View
Abdominal pain SYSTEMATIC_ASSESSMENT Gastrointestinal disorders GOOSS View
Food impaction SYSTEMATIC_ASSESSMENT Gastrointestinal disorders GOOSS View
Other Events(If Any):