Viewing Study NCT04181528


Ignite Creation Date: 2025-12-26 @ 11:11 AM
Ignite Modification Date: 2026-03-06 @ 5:28 PM
Study NCT ID: NCT04181528
Status: UNKNOWN
Last Update Posted: 2019-11-29
First Post: 2019-10-31
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: A Comparison of Anatomically Aligned Versus Conventional in Unilateral Total Knee Arthroplasty
Sponsor: The Catholic University of Korea
Organization:

Study Overview

Official Title: A Comparison of Anatomically Aligned Versus Conventional in Unilateral Total Knee Arthroplasty
Status: UNKNOWN
Status Verified Date: 2019-11
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Total knee arthroplasty(TKA) is a successful orthopedic surgery with excellent clinical outcome and survival. However, there are concerns about patient satisfaction in previous reports, and dissatisfaction rate of 15-30% is reported in clinical outcomes(PROMs) of some studies. Therefore, for improving the patient's outcome and satisfaction after total knee arthroplasty, it is necessary to change the design of the conventional total knee arthroplsaty implant. The knee is a joint structure with several dynamic functions, and not only the skeletal structure but also the soft tissue balance plays an important role in the function of the knee joint. New implants are being developed to overcome the limitations of conventional TKA implant, including the Journey II Bi-cruciate substituting total knee system (JII-BCS; Smith \& Nephew). JII-BCS implant has normal articular geometry, more anatomical femoral shape, lateral tibial convex geometry, and asymmetrical tibial plateau, anterior and posterior cams, which has been shown in experimental studies to produce nearly normal knee movement by reproducing the actual normal anatomical alignment in vivo. The clinical results of the kinematic effects of this anatomcally aligned change are insufficient, and there is also a lack of comparative studies with conventional total knee arthroplasty implant. The purpose of this study is to compare outcomes between anatomically aligned TKA(JII-BCS) and conventional TKA(Legion total knee system, Smith \& Nephew). This study is a randomized controlled study in patients undergoing unilateral total knee arthroplasty. A patient will undergo unilateral TKA with anatomically aligned or conventional TKA implant. The implant is determined using a random number table. Radiologic parameter, patients preference and clinical results was investigated in patients who received unilateral TKA during minimum 2 year follow up.
Detailed Description: None

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: