Viewing Study NCT03183895


Ignite Creation Date: 2025-12-24 @ 1:31 PM
Ignite Modification Date: 2026-02-26 @ 7:25 PM
Study NCT ID: NCT03183895
Status: ACTIVE_NOT_RECRUITING
Last Update Posted: 2025-01-29
First Post: 2017-06-07
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Evaluate the Safety and Performance of the AccuCinch® Ventricular Repair System - The CorCinch-EU Study
Sponsor: Ancora Heart, Inc.
Organization:

Study Overview

Official Title: Safety and Performance Evaluation of the AccuCinch® Ventricular Restoration System for the Treatment of Heart Failure With or Without Functional Mitral Regurgitation Due to Dilated Ischemic or Non-Ischemic Cardiomyopathy - The CorCinch-EU Study
Status: ACTIVE_NOT_RECRUITING
Status Verified Date: 2025-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This is prospective, non-randomized, single-arm, international, multicenter, clinical safety and performance clinical investigation to evaluate the AccuCinch® Ventricular Repair System for the treatment of heart failure, with or without functional mitral regurgitation due to dilated ischemic or non-ischemic cardiomyopathy
Detailed Description: The primary objectives of this study are to evaluate the safety and performance of the AccuCinch Ventricular Repair System for the treatment of heart failure and functional mitral regurgitation in symptomatic adult patients with or without functional mitral regurgitation (FMR) and left ventricular remodeling due to dilated cardiomyopathy (ischemic or non-ischemic etiology), who remain symptomatic despite optimized medical therapy.

Subjects with FMR must present with at least moderate FMR, a reduced ejection fraction (≤40%) and high operative risk as assessed by the Heart Team. The Heart Team may utilize established risk scores (STS, Euro-Score II) in conjunction with comorbidities as recommended by MVARC (frailty index; major organ system compromise not to be improved postoperatively; procedure specific impediments).

Subjects without FMR must present a markedly dilated left ventricle with LVEDD ≥ 55 mm and reduced ejection fraction (≤40%). These patients are not potential candidates for "conventional intervention", because their mitral valve is not in need of repair or replacement. Therefore, AccuCinch represents the sole treatment option for these patients, who are not selected on the basis of high surgical risk.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: True
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: