Viewing Study NCT01879150


Ignite Creation Date: 2025-12-24 @ 5:23 PM
Ignite Modification Date: 2026-02-25 @ 5:34 PM
Study NCT ID: NCT01879150
Status: UNKNOWN
Last Update Posted: 2013-06-17
First Post: 2012-09-02
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Pilot Study of CyclaPlex Implant, an Enhanced Suture and Button Implant Device in Hallux Valgus Deformity
Sponsor: Meir Medical Center
Organization:

Study Overview

Official Title: Single Center, Open-label, Single Arm, Study Designed to Evaluate Safety, Tolerability and Efficacy of CyclaPlex Implant and Tools for Correction of First Inter-metatarsal Angle in Subjects Suffering From Hallux Valgus Deformity
Status: UNKNOWN
Status Verified Date: 2013-06
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: CO001
Brief Summary: Single center, open-label, single arm, pilot study designed to evaluate safety, tolerability and efficacy of CYCLAPLEX device, a minimal invasive enhanced suture and button implant and surgery tools for correction of inter-metatarsal angle in subjects suffering from mild to moderate Hallux Valgus deformity
Detailed Description: INVESTIGATIONAL THERAPY Cycla Orthopedics Ltd has developed the CYCLAPLEX , a minimally invasive enhanced type of Suture and Button implant. It is intended to: (a) reduce the intermetatarsal angle (IMA) between 1MT and 2MT without osteotomy osteotomy b) reduce the risk of 2MT fractures (d) perform the implantation procedure in an easy and safe way.

The CYCLAPLEX predicated device is the "Suture and Button" type MiniTightrope. It is based on Mini Tightrope clinical experience, however with additional features to increase safety and functionality.

The CyclaPlex device comprise of two bone holders ('Anchors ') connected by a metal cord. The cord is connected to the buttons by crimp method as part of the surgery procedures The bone holders are T shape screws that are screwed into the bones after drilling holes across the 2 metatarsals. The gap in the bone as a result of the drilling is filled by the enhanced T shape buttons (screws). A nut is residing internally as part of the 1st met anchor structure. The IMA is reduced using specially designed tensioning tool CyclaPlex device is indicated for reducing intermetatarsal angles in cases where IMA is less than 200 eliminating the need for the traditional 1st metatarsal osteotomy. It used in conjunction with traditional release of the lateral MTP joint capsular structures and removal of the medial eminence as well as regular HVA reduction procedures such as AKIN.

The 2nd Metatarsal fracture risk is reduced due multiple/ accumulated factors:

(i) The hole drilled at 2nd metatarsal had been reduced significantly (ii) The hole is filled by conical screw and head. This firm anchoring method enable to distribute the horizontal forces applied during gate.

(iii) The metal screw type device enables bone growth over it and strengthen the bone at that area.

(iv) The connecting cord is housed inside the screw and has no direct touch with the bone, in both, 2nd and 1st metatarsals.

The device is delivered sterilized ( steam sterilization) double bag residing in cardboard box.

Dedicated assistive tools for multiple use are provided as well housed in a special tray intended for surgery room steam sterilization. The tools comprise of Aiming Drilling Guide,, screw driver for anchors insertion, Tensioning tool for reduction of the IMA, Crimping tool, cutter, single use drill bits

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: