Viewing Study NCT05726461


Ignite Creation Date: 2025-12-24 @ 11:47 AM
Ignite Modification Date: 2026-02-27 @ 5:17 PM
Study NCT ID: NCT05726461
Status: UNKNOWN
Last Update Posted: 2023-07-27
First Post: 2023-01-18
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Efficacy and Safety of Android Artificial Pancreas System in Adult Patients With Type 1 Diabetes Mellitus in China
Sponsor: Third Affiliated Hospital, Sun Yat-Sen University
Organization:

Study Overview

Official Title: Efficacy and Safety of Android Artificial Pancreas System Use at Home Among Type 1 Diabetes Mellitus Adults in China: Protocol of a 26-Week, Free-Living, Randomized, Open-Label, Two-Arm, Two-Phase, Crossover Trial
Status: UNKNOWN
Status Verified Date: 2023-07
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This is a 26-week randomized, free-living, open-label, two-arm, two-phase, crossover trial. Participants will receive two interventions at different phases, including the Android artificial pancreas system(AndroidAPS-rt-CGM) and sensor-augment pump(SAP), and use marketed rapid-acting insulin analogs (insulin Aspart, insulin Lispro, or insulin Glulisine) normally used in their usual clinical care. The safety and efficacy of AndroidAPS-rt-CGM and SAP in adult T1DM with suboptimal glycemic control will be compared to explore whether the use of AndroidAPS-rt-CGM in adult T1DM with suboptimal glycemic control will be associated with better glycemic control with no increased hypoglycemia.
Detailed Description: All participants will be free to live during the study. Each intervention phase is 12 weeks, preceded by a 2-week training period and separated by a 2-week washout period. During the training period, eligible participants will be trained to use the study rt-CGM and insulin pump and randomly assigned 1:1 to two treatment sequences after the training period. In Sequence A, patients use AndroidAPS-rt-CGM for the first intervention period (phase 1) and SAP for the second intervention period (phase 2); in Sequence B, patients use SAP for Phase 1 and AndroidAPS-rt-CGM for Phase 2. Participants who enter sequences A and B will be trained to use the study devices running in automated insulin delivery(AID) mode on the first day of phase 1 and phase 2, respectively. AndroidAPS-rt-CGM consists of three components:1) AiDEX G7 continuous glucose monitoring (an rt-CGM);2) Equil® insulin patch pump;3) AndroidAPS algorithm implemented in Android smartphone. The participants will use the study patch pump and rt-CGM, but the AndroidAPS algorithm and advanced features will not be allowed during the SAP intervention period. During the washout period, participants will continue using the study insulin pump with their standard settings, but the study rt-CGM will be replaced by daily self-monitoring of fingerstick glucose. The primary endpoint is time in range (3.9-10.0 mmol/L) derived from CGM. The main secondary endpoints include the percentage of sensor glucose values below, within, and above the target range; mean sensor glucose value; measures of glycemic variability, and centralized HbA1c. Safety endpoints mainly include the frequency of hypoglycemia events, diabetic ketoacidosis, and other serious adverse events.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: