Viewing Study NCT01190059


Ignite Creation Date: 2025-12-24 @ 2:54 PM
Ignite Modification Date: 2026-01-03 @ 8:17 PM
Study NCT ID: NCT01190059
Status: COMPLETED
Last Update Posted: 2025-04-04
First Post: 2010-08-25
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Normothermic Ex Vivo Lung Perfusion (EVLP) For An Improved Assessment of Donor Lungs For Transplantation
Sponsor: XVIVO Perfusion
Organization:

Study Overview

Official Title: Normothermic Ex Vivo Lung Perfusion (EVLP) For An Improved Assessment of Donor Lungs For Transplantation
Status: COMPLETED
Status Verified Date: 2025-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: HELP
Brief Summary: The use of ex vivo lung perfusion (EVLP) will allow for a secondary evaluation technique for donor lungs that fail to meet standard acceptability criteria. This advanced assessment might lead to increased utilization rates of donor lungs and improved outcomes after lung transplantation.
Detailed Description: Human donor lungs that do not meet the standard clinical criteria for donor lung utilization but fit into the study inclusion criteria will be retrieved from the donor using current donor lung retrieval techniques.

These lungs will be brought to the study transplant center to be re-assessed by the transplant team. The lungs will be physiologically assessed during ex vivo perfusion with Steen Solution. Perfusion of these lungs will be performed using Steen solution with the addition of methylprednisolone, heparin and antibiotics. With respect to the decision of lung utilization those organs with a delta pO2 (Δ pO2 = Pulmonary vein pO2 - pulmonary artery pO2) during ex vivo perfusion assessment \> 350mmHg, good lung compliance, and a favorable opinion of the transplant surgeon will be considered transplantable. Lungs will be excluded for transplantation: if the Δ pO2 is less than 350mmHg or if they demonstrate \>10% deterioration in any of the following functional parameters: pulmonary vascular resistance (PVR), dynamic compliance or airway pressures. Lungs will also be excluded if they are deemed unsuitable based on the clinical judgment of the lung transplant surgeon.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
139150 OTHER Health Canada View