Viewing Study NCT03250793


Ignite Creation Date: 2025-12-25 @ 1:05 AM
Ignite Modification Date: 2026-03-03 @ 10:03 AM
Study NCT ID: NCT03250793
Status: COMPLETED
Last Update Posted: 2025-09-04
First Post: 2017-08-03
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Work of Breathing Description in Neonates With Congenital Diaphragmatic Hernia in NAVA and in Conventional Ventilation.
Sponsor: Hospices Civils de Lyon
Organization:

Study Overview

Official Title: Physiologic Pilot Study: Work of Breathing Description in Neonates With Congenital Diaphragmatic Hernia in Post-surgical Period Alternatively in Conventional Ventilation (Pressure Controlled) and in NAVA (Neurally Adjusted Ventilatory Assist) Ventilation.
Status: COMPLETED
Status Verified Date: 2025-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: NAVA-DIAPH
Brief Summary: Congenital diaphragmatic hernia (CDH) is a congenital malformation associated with significant mortality and respiratory morbidity, particularly related to prolonged mechanical ventilation. NAVA (Neurally Adjusted Ventilatory Assist) is a recent technique that uses the recognition of the electrical activity of the patient's diaphragm (Edi) and delivers a synchronized proportional assisted ventilation. This technique has already been used in the newborn, especially premature and has shown many benefits. Only one study in the literature shows its feasibility in newborns with CDH. This technique seems interesting in the context of CDH because it would limit baro-trauma and improve synchronization. Before demonstrating the clinical benefits, it seems important to describe the effects on the respiratory physiology, in particular on work of breathing which can be estimated by the esophageal and trans-diaphragmatic pressure-time product obtained by an esophageal transducer. Our study is an innovative physiologic pilot study with the objective to describe work of breathing in neonates with CDH in post-surgical period in NAVA ventilation and in conventional ventilation using an esophageal transducer. It will provide the clinician with a physiological justification for the use of NAVA to rapidly improve the respiratory muscular dynamics of these patients. This study is a prerequisite for the realization of studies demonstrating the clinical benefit of NAVA ventilation on reduction of duration of ventilation and more generally on morbidity and mortality in the population of neonate with CDH.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: False
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
2017-A02270-53 OTHER ID-RCB View