Viewing Study NCT02011867


Ignite Creation Date: 2025-12-25 @ 12:36 AM
Ignite Modification Date: 2026-03-07 @ 2:28 PM
Study NCT ID: NCT02011867
Status: COMPLETED
Last Update Posted: 2013-12-13
First Post: 2013-11-30
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: A New Cochlear Implant Electrode For Inner Ear Malformations
Sponsor: Hacettepe University
Organization:

Study Overview

Official Title: A New Cochlear Implant Electrode With A "Cork" Type Stopper For Inner Ear Malformations
Status: COMPLETED
Status Verified Date: 2013-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations. Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF (cerebrospinal fluid) pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.
Detailed Description: Gusher in inner ear malformations is common in patients with incomplete partition type-I, and III. It is also common in less severe form as oozing in incomplete partition type II and large vestibular aqueduct. It is important to prevent CSF escape around the cochlear implant electrode to prevent meningitis.

The custom made device was produced by Med-El Company. It has a "cork" like stopper instead of the usual silicon ring to prevent gusher. There are two types of electrodes consisting of different length. Standard one is 25 mm (contact space 1.7 mm) and the short one is 20 mm (contact space 1.3 mm). It was used in 50 patients with different inner ear malformations.

Thirteen patients had gusher, and 11 patients oozing during cochleostomy. One patient with initial prototype of the cork electrode had to be revised because of persistent oozing around the electrode. Another patient had slow extrusion of the electrode most probably due to CSF pulsation and had to be revised. Both patients had no more CSF fistula.

CSF fistula in inner ear malformations is a serious situation which may lead to recurrent meningitis. The new cochlear implant electrode with "cork" stopper looks promising in preventing the postoperative CSF leak around the electrode.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: