Viewing Study NCT02361658


Ignite Creation Date: 2025-12-25 @ 12:06 AM
Ignite Modification Date: 2026-02-21 @ 11:17 PM
Study NCT ID: NCT02361658
Status: COMPLETED
Last Update Posted: 2025-03-17
First Post: 2015-02-03
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Optic Nerve Sheath Diameter (ONSD) With the Raised PCO2 and Internal Jugular Venous Occlusion
Sponsor: Lashmi Venkatraghavan
Organization:

Study Overview

Official Title: Ultrasonographic Assessment of the Optic Nerve Sheath Diameter During Variations in PetCO2 and Controlled Internal Jugular Venous Occlusion: A Volunteer Study
Status: COMPLETED
Status Verified Date: 2025-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Monitoring the ICP is the most important aspect of the management of these patients. Recently, transorbital ultrasonography has gained popularity as a noninvasive bedside exam that has been shown to be useful in the diagnosis of raised ICP by evaluating the change in the optic nerve sheath diameter (ONSD). Transorbital ultrasonographic measurement of ONSD appears to be a noninvasive, relatively inexpensive bedside examination for the diagnosis of raised ICP. The investigators aimed to determine the changes in ONSD with acute controlled changes in ICP in healthy volunteers. The controlled changes in ICP will be produced by manipulating the PCO2 with the use of Respiract and jugular venous compression with the use of custom made neck collar.
Detailed Description: Elevated intracranial pressure (ICP) is a common and potentially life threatening condition arising from a variety of pathological conditions including traumatic brain injury (TBI), intracranial hemorrhage, subarachnoid hemorrhage and brain tumors. Monitoring the ICP is the most important aspect of the management of these patients. Recently, transorbital ultrasonography has gained popularity as a noninvasive bedside exam that has been shown to be useful in the diagnosis of raised ICP by evaluating the change in the optic nerve sheath diameter (ONSD). Transorbital ultrasonographic measurement of ONSD appears to be a noninvasive, relatively inexpensive bedside examination for the diagnosis of raised ICP. The investigators aimed to determine the changes in ONSD with acute controlled changes in ICP in healthy volunteers. The controlled changes in ICP will be produced by manipulating the PCO2 with the use of Respiract and jugular venous compression with the use of custom made neck collar.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: