Viewing Study NCT04274504


Ignite Creation Date: 2025-12-24 @ 9:19 PM
Ignite Modification Date: 2026-02-20 @ 8:25 PM
Study NCT ID: NCT04274504
Status: COMPLETED
Last Update Posted: 2020-02-18
First Post: 2020-02-14
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Osteopontin in Metastatic Breast Cancer Patients
Sponsor: Mansoura University
Organization:

Study Overview

Official Title: Osteopontin Level and Promoter Polymorphism in Egyptian Metastatic Breast Cancer Patients
Status: COMPLETED
Status Verified Date: 2020-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: OPN plays an important role in various aspects of malignancy, particularly those involved in tissue invasion and metastasis, and OPN levels have been associated with aggressive¬ness in several cancer types, including breast cancer. Tumor response to treatment is a predictor of prognosis and overall survival for cancer patient population the investigators assigned osteopontin as potential contributors in breast cancer.
Detailed Description: Analysis of polymorphisms in the OPN regulatory region:

The PCR amplification of the promoter regulatory region from the extracted DNA by using the following primers -3 (forward primer 5" -CAA GCT ACT GCA TAC TCG AAA TCA CA-3" ; reverse primer 5" - ACA ACC AAG CCC TCC CAG AAT TTA-3" ). PCR was performed using 50 ng DNA as a template under the following conditions: 95°C for 10 min, then 36 cycles of 94°C for 30 s, an annealing temperature for 60 s, and 72°C for 60 s, with a final extension at 72°C for 15 min. After affinity membrane purification using the QIAquick Gel Extraction kit (Qiagen, Carlsbad, CA, USA), the PCR products were subjected to cycle sequencing with the respective forward and reverse primer using an automated ABI 310 DNA sequencer.

Measurement of serum level of osteopontin:

OPN level were measured using Enzyme linked immnosorbent (ELISA) Kit supplied by IBL (Immuno-Biological laboratories Co. Ltd., Japan). 30 normal females were conducted with matched age with a median osteopontine serum level of 15 so, this level was assigned as a cut off value.

Pretreatment serum level and polymorphism of oteopontine was correlated with different clinicopathological criteria of the patients, response to the treatment, PFS and OS.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: