Study Overview
Official Title:
Establish a Telecare Model of Acute Coronary Syndrome Patient With Heart Stent Implantation by a Non-invasive Wearable Device and Artificial Intelligence Cloud System to Heart Failure Monitoring and Reducing Medical Adverse Events.
Status:
UNKNOWN
Status Verified Date:
2020-06
Last Known Status:
NOT_YET_RECRUITING
Delayed Posting:
No
If Stopped, Why?:
Not Stopped
Has Expanded Access:
False
If Expanded Access, NCT#:
N/A
Has Expanded Access, NCT# Status:
N/A
Brief Summary:
Heart disease is still one of the world's most important health problems, and it ranks second among the top ten causes of death among Taiwan. The main cause of death is acute coronary syndrome, and vascular stent placement is the main treatment method for acute coronary syndrome. The probability of restenosis in patients within half a year after a general stent is as high as 25% to 40%. Re-hospitalization and surgery is a big burden on patients and the country's medical costs. However, a set of convenient and accurate clinical tools to determine the prognosis of patients has not yet been developed. Miniaturized wearable devices have been the mainstream trend in medical development in recent years. ECG and heart sound analysis technology are an easy to used medical device for automatically calculating the parameters including EMAT (electromechanical activation time), S4, S4, SDI (Systolic dyssynchrony index). ECG and heart sound could evaluate the heart function, and has the potential to be an effective tools for prognosis and treatment guidelines. Heart rate variability (HRV) and Accelerationplethysmogram (APG) is also proved the predictive effect the outcome of patients.
This study is start on June 1 2020. We will enroll 400 patients who diagnosis of acute coronary syndrome and have been a heart stent surgery, and registry there medical history,routine examination and medication, ECG and heart, HRV and APG record at admission, pre-discharge and every routine return visit within I year after discharge.Patients will also wear ECG and PPG (Photoplethysmography) band ever day after discharge, and collected the longitutinal data .All subjects will be tracked the medical adverse events in 1 years after discharge, and compare the characteristic and prognosis value of between patients with and without events. Therefore, our purpose of this study is to drive an effective outcome prediction model by non-invasive device, and establish a telecare model of patient with heart stent implantation to reducing medical adverse events.
Detailed Description:
This study is open, prospective study, multi-center, randomized controlled trial, unobtrusive research. This study is start on June 1 2020. We will enroll 400 patients who diagnosis of acute coronary syndrome and have been a heart stent surgery. And random allocation 200 experimental group (Non-invasive Wearable Device) and 200 control group (routine medical).
Ask whether the patients who meet the exclusion criteria are willing to participate in the screening (Screening), if they are willing to join and sign the consent of the subject, and after the patient's condition is stable, conduct an electrocardiogram (V0) before discharge from the hospital. On day 7 (±2 weeks), day 84 (±4 weeks), 168 days (±4 weeks), 252 days (±4 weeks), 336 days (±8 weeks) during routine clinical referral (V1-V5) Both are done once. The results of these two tests and other basic information of the patient, including Demography, Vital Signs, High, Weight, Medication, and European and Taiwan Cardiology Association recommended routine test results of high-risk patients, including Blood Chemistry Panel, NT-proBNP, Echocardiography, Myocardial Perfusion Scan, etc., will record the information of the logged-in subjects on the paper case report form. The CRF (case report form) only displays the study number, and no subject is available. In addition to the examination of each return visit, the subjects also took the ECG bracelet home at the time of discharge (V0) and wore it every day. After the discharge, the ECG was measured every morning and evening, and their personal activity and sleep were collected. Relevant information. After the subject was discharged from the hospital, the subject tracked the date of all adverse events due to cardiovascular disease within one year, including: heart failure, restenosis due to blood vessel, and non-fatal myocardial infarction , To do blood vessel-related surgery again, and data on the occurrence of death.
Study Oversight
Has Oversight DMC:
False
Is a FDA Regulated Drug?:
False
Is a FDA Regulated Device?:
False
Is an Unapproved Device?:
None
Is a PPSD?:
None
Is a US Export?:
None
Is an FDA AA801 Violation?: