Brief Title: Total Knee Arthroplasty With the Medial-Pivot Knee System
Sponsor: Centre Hospitalier Universitaire, Amiens
Organization:

Study Overview

Official Title: Total Knee Arthroplasty With the Medial-Pivot Knee System: Clinicaland Radiological Outcomes at 9.5 Years' Mean Follow-up
Status: COMPLETED
Status Verified Date: 2018-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: MEDIAL-PIVOT
Brief Summary: The "ball-in-socket" design of the Medial-Pivot knee system (MicroPort Orthopedics, Arling-ton, Tennessee, USA) aims to reproduce normal knee kinematics by medializing its rotational axis. Thegoal of this study was to measure knee range of motion (ROM) with this implant after a mean follow-up of 10 years and to report the survivorship and long-term clinical and radiological outcomes. Wehypothesized the prosthetic knee would have at least 120◦flexion at 10 years. This was retrospective, single-centre study of 74 Medial-Pivot knees implanted in71 patients (average age of 69 years) between May 2005 and November 2007. All patients who receiveda Medial-Pivot knee were included consecutively. The mean follow-up was 10 years. Clinical and radio-logical assessments were performed using the Knee Society Score (KSS) and Ewald's score. Kaplan-Meirsurvival analysis was used to calculate survivorship.
Detailed Description: methodsThis was retrospective, single-centre study of 74 Medial-Pivotknees implanted in 71 patients between May 2005 and Novem-ber 2007. During this period, several types of semi-constrainedprimary TKA implants were used.The "ball-in-socket" design of the Medial-Pivot knee system (MicroPort Orthopedics, Arling-ton, Tennessee, USA) aims to reproduce normal knee kinematics by medializing its rotational axis. Thegoal of this study was to measure knee range of motion (ROM) with this implant after a mean follow-up of 10 years and to report the survivorship and long-term clinical and radiological outcomes. Wehypothesized the prosthetic knee would have at least 120◦flexion at 10 years. This was retrospective, single-centre study of 74 Medial-Pivot knees implanted in71 patients (average age of 69 years) between May 2005 and November 2007. All patients who receiveda Medial-Pivot knee were included consecutively. The mean follow-up was 10 years. Clinical and radio-logical assessments were performed using the Knee Society Score (KSS) and Ewald's score. Kaplan-Meirsurvival analysis was used to calculate survivorship.