Viewing Study NCT02387502


Ignite Creation Date: 2025-12-25 @ 4:02 AM
Ignite Modification Date: 2026-02-28 @ 10:52 PM
Study NCT ID: NCT02387502
Status: COMPLETED
Last Update Posted: 2015-05-04
First Post: 2015-03-02
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Comparison of Three Laryngoscopes in Difficult Laryngoscopy
Sponsor: Government Medical College, Haldwani
Organization:

Study Overview

Official Title: Comparative Evaluation of Macintosh, MacCoy and Airtraq Laryngoscope in Simulated Difficult Laryngoscopy Using Rigid Neck Collar
Status: COMPLETED
Status Verified Date: 2015-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Tracheal intubation requires alignment of oro-pharyngeal-laryngeal axes. When these three axes are not aligned, intubation becomes difficult. In the researchers' study, the investigators simulated difficult laryngoscopy situation by using a rigid neck collar. This neck collar renders intubation difficult not only by restricting neck movement, but also reducing mouth opening. The investigators compared the performance of Macintosh, MacCoy and Airtraq laryngoscope in simulated difficult laryngoscopy using a rigid neck collar.
Detailed Description: Airtraq laryngoscope is an optical laryngoscope which allows visualization of vocal cord as a reflected image through multiple lenses and prisms. MacCoy laryngoscope is a modification of Macintosh laryngoscope. It has a lever which, when pressed, moves its flexible tip. In the investigators' study, the researchers compared the performances of Airtraq laryngoscope with MacCoy and Macintosh laryngoscopes in simulated difficult laryngoscopy using a rigid neck collar. The researchers recruited 120 patients and randomly divided those patients into three equal groups i.e. 30 patients in each group. These three groups are 1-Airtraq, 2-MacCoy and 3-Macintosh. The researchers compared efficacy and safety in these three laryngoscopes. The researchers compared efficacy in terms of time of intubation, ease of intubation, overall success, Intubation difficulty score, visualization of vocal cord in terms of POGO (percentage of Glottic Opening) score. The researchers compared safety in terms of hemodynamic pressor response and airway trauma.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: