Viewing Study NCT03285334


Ignite Creation Date: 2025-12-25 @ 2:28 AM
Ignite Modification Date: 2026-01-04 @ 7:57 AM
Study NCT ID: NCT03285334
Status: UNKNOWN
Last Update Posted: 2017-09-18
First Post: 2017-09-13
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: 3D Instrumentation Versus Rotary Instrumentation
Sponsor: Cairo University
Organization:

Study Overview

Official Title: The Effect of 3D Instrumentation Versus Rotary Instrumentation on Postoperative Pain and Bacterial Reduction in Necrotic Oval Canals: A Randomized Clinical Trial
Status: UNKNOWN
Status Verified Date: 2017-09
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: enrollment of the patient after diagnosis, radiographic evaluation, and signing the informed consent.

allocation of the patient to either intervention or control group. After anaesthesia and access cavity, the first root canal sample will be taken. Endodontic treatment will be completed in one visit. The second root canal sample will be taken. Patients will be asked to evaluate their postoperative pain level using VAS scale at 6, 12, 24 hours, and daily up to 5 days. Patients will record the number of analgesics if any taken.
Detailed Description: After diagnosing the case as asymptomatic pulp necrosis and confirming that the patient conforms to all eligibility criteria, (R.S) will enroll the patient in the study.

the operator will complete treatment of all cases in single visit as following:

1. Anesthetizing the tooth using inferior alveolar nerve block technique
2. Removal of Caries and/or coronal restorations completely with sterile bur and rubber dam will be applied.
3. Preparation of access cavity using another sterile round carbide bur size 3 and Endo-z bur .
4. (R.S) will take the preinstrumentation root canal sample (S1)
5. Confirming the patency of the root canals using stainless steel hand K-files size #10 and #15 . Working length will be determined .
6. In the intervention group, (R.S) will perform mechanical preparation in a 3D manner using Xp-endo Shaper single file in an endodontic motor at a speed of 800 rpm and a torque of 1 Ncm.
7. In the control group, mechanical preparation will be done using rotary iRace files (#25/0.04, #30/0.04, and #40/0.04) at a speed of 600 rpm and a torque of 1.5 Ncm. The canal will be irrigated and recapitulated after the use of each instrument.
8. EDTA gel will be used as a lubricant. The canals will be thoroughly irrigated using 3ml of 2.5% sodium hypochlorite.
9. The canal will then be dried by using sterile paper points and then flushed with 5 ml of 5% sodium thiosulfate to inactivate the NaOCl. The postinstrumentation sample (S2) will be taken from the canals.
10. Master cones will be fitted to the working length and a radiograph will be taken to ensure proper length.
11. (R.S) will complete obturation using AdSeal resin-based root canal sealer .

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: