Viewing Study NCT03307694


Ignite Creation Date: 2025-12-25 @ 1:46 AM
Ignite Modification Date: 2026-03-02 @ 4:01 PM
Study NCT ID: NCT03307694
Status: COMPLETED
Last Update Posted: 2019-12-03
First Post: 2017-10-03
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Thyroid Ultrasound Elasticity (TrUE) Imaging
Sponsor: Emory University
Organization:

Study Overview

Official Title: Multi-Angle Compound Shear Wave Elasticity Imaging for the Characterization of Thyroid Nodules
Status: COMPLETED
Status Verified Date: 2019-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: In this study the researchers will scan the thyroid nodules of patients scheduled for surgical removal of these nodules. During their preadmission testing, but prior to their surgery, the researchers will perform standard ultrasound and shear wave elasticity imaging (SWEI) scans of the thyroid nodules in these patients. Both images can be generated by the same ultrasound scanner and within the same imaging session without having to switch out any equipment. The results of the SWEI scans will be compared to the definitive diagnosis from pathology obtained after pathologists have examined the removed nodules post-operatively.
Detailed Description: Thyroid ultrasound is a first-line procedure to assess patients with thyroid nodules. Unfortunately, standard ultrasound has low sensitivity, and thus low positive predictive value, for malignancy and many patients with thyroid nodules are referred for additional imaging studies or biopsy. Shear wave elasticity imaging (SWEI) is a non-invasive ultrasound technology that allows clinicians to assess the stiffness of tissues. In many solid tumors, increased stiffness is highly specific for underlying malignancy, and preliminary studies have shown this to be true for thyroid malignancies. Both standard sonography and SWEI can be performed on the same ultrasound equipment and within the same imaging session. Therefore, integrating SWEI into standard thyroid diagnostic workflow is a logical approach towards improving the positive predictive value of these first-line sonographic studies. Other studies have demonstrated the ability of SWEI techniques to differentiate benign from malignant thyroid nodules. However, shear wave techniques still need to overcome challenges before they can be successfully integrated into the clinical paradigm. These techniques still struggle to accurately classify follicular carcinomas and few have been validated in patients with multiple thyroid lesions, a scenario which is clinically common. The researchers believe that a multi-angle compound SWEI (MAC-SWEI) algorithm, which generates shear images based on multiple angled push beams, has the potential to generate more accurate shear wave images in the context of thyroid imaging. To this end, this study will perform proof-of-concept studies of MAC-SWEI in thyroid patients undergoing standard ultrasound scans and compare the results of shear wave images to results from corresponding pathology.

Study participants will undergo a single SWEI session within their normally-scheduled preadmission testing during which both standard b-mode and shear images of the thyroid nodule(s) will be acquired. The 36 patients will be randomized to receive MAC-SWEI, standard SWEI, and ultrasound, or only standard SWEI and ultrasound.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: