Viewing Study NCT02863094


Ignite Creation Date: 2025-12-25 @ 1:45 AM
Ignite Modification Date: 2026-03-02 @ 10:34 PM
Study NCT ID: NCT02863094
Status: COMPLETED
Last Update Posted: 2021-10-12
First Post: 2016-07-07
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Repetitive Transcranial Magnetic Stimulation (rTMS) Treatment for Schizophrenia Patients With Auditory Hallucinations
Sponsor: Anhui Medical University
Organization:

Study Overview

Official Title: None
Status: COMPLETED
Status Verified Date: 2021-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: To investigate the treatment effect of continuous transcranial magnetic stimulation on schizophrenia patients with auditory hallucinations, and the underlying neural mechanism by functional MRI
Detailed Description: All patients underwent a medical evaluation that included physical examination and routine laboratory studies before and after repetitive transcranial magnetic stimulation (rTMS) treatment. Patients were randomly allocated to rTMS group and the sham group by random number. There are about 30 patients in each group.The decision to enroll a patient was always made prior to randomization. Patients were studied using a double-blind design. Study participants, clinical raters, and all personnel responsible for the clinical care of the patient remained masked to allocated condition and allocation parameters. Only rTMS administrators had access to the randomization list; they had minimal contact with the patients, and no role in assessing AVH and other measures. Each patient would be treated for continuous 15 days by rTMS

Before the rTMS treatment, the Auditory Hallucination Rating Scale, Psychotic Symptom Rating Scale, and the Positive and Negative Syndrome Scale were obtained by a trained investigator to assess baseline severity of auditory verbal hallucination (AVH) and other symptoms. The patients had receiving a battery measure of neuropsychological tests (standardized tests to investigate their cognitive problems, anxiety and depressive symptoms in daily life), magnetic resonance imaging scan in multimodalities, electroencephalography (EEG), event-related potentials during stop signal test and Iowa-gambling test record.

After the last treatment, the Auditory Hallucination Rating Scale, Psychotic Symptom Rating Scale, and the Positive and Negative Syndrome Scale were obtained, as well as the Global Index of Safety to assess adverse events of the treatment. Patients were instructed to focus their answers on the past 15 days. The patients had also receiving a battery measure of neuropsychological tests, magnetic resonance imaging scan in multimodalities, and EEG record.

A month after the last treatment, participants were interviewed to obtain the Auditory Hallucination Rating Scale, Psychotic Symptom Rating Scale, the Positive, and Negative Syndrome Scale. They were instructed to focus their answers on the past week. Additionally, they were also asked to assess the battery of neuropsychological tests, and have magnetic resonance imaging scan in multimodalities, and EEG record. Afterwards, they were unblinded by the study coordinator.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: