Study Overview
Official Title:
The Effects on Hand Function With Robot-assisted Rehabilitation for Patients With Stroke
Status:
COMPLETED
Status Verified Date:
2018-06
Last Known Status:
None
Delayed Posting:
No
If Stopped, Why?:
Not Stopped
Has Expanded Access:
False
If Expanded Access, NCT#:
N/A
Has Expanded Access, NCT# Status:
N/A
Brief Summary:
Robotic therapy can deliver larger amounts of upper extremity movement practice for stroke rehabilitation. Although the treatment effects were supported in studies, there are still limitations in clinical intervention. The study will use the robot-assisted hand rehabilitation with a Gloreha device. Thirty patients with moderate motor deficits were recruited and randomized into 2 treatment groups, AB or BA (A = 12 times of robot-assisted hand rehabilitation, B = 12 times of standard therapy) for 12 weeks of treatment (Sixty minutes a time, twice a week), 1 month of break between conditions for washout period. The performance was assessed by a blinded assessor for five times (pre-test1, post-test 1, pre-test2, post-test 2, follow up at three month). The outcome measures Fugl-Meyer Assessment-Upper Limb section(FMA-UE),Box and block test(BBT), Maximal voluntary contraction(MVC) of extensor digitorum communis(EDC), Abductor pollicis brevis(APB), Flexor digitorum(FD), Dynanometer, Semmes-Weinstein hand monofilament (SWM), Revision of the Nottingham Sensory Assessment (EmNSA), Modified Barthel Index. Collected data will be analyzed with ANOVA test by SPSS version 20.0, and alpha level was set at 0.05. The hypothesis are robot-assisted hand rehabilitation with a Gloreha device has positive effects on sensory, motor, hand function, and ADL ability among patients with stroke.
Detailed Description:
Many stroke survivors suffered problems with the upper extremity, such as paresis, synergy movement, hypertonicity, jag movement, sensory deficit. An inability to use the upper extremity in daily life can lead to loss of independence with ADLs and of important occupations (eg,work, driving). For individuals with more severe paresis, the potential for recovery of upper extremity function is greatly reduced. Robotic therapy can deliver larger amounts of upper extremity movement practice for these individuals. Although the Robotic therapy appears to provide some benefit for upper extremity motor abilities and participation but is of uncertain utility compared with dose-matched conventional upper limb exercise therapies. Objective: To investigate the effects of robot-assisted hand rehabilitation with a Gloreha device on sensory, motor, and ADL ability for patients with stroke.
Materials and Methods: Thirty patients with moderate motor deficits were recruited and randomized into 2 treatment groups, AB or BA (A = 12 times of robot-assisted hand rehabilitation, B = 12 times of standard therapy) for 12 weeks of treatment (Sixty minutes a time, twice a week), 1 month of break between conditions for washout period. The performance was assessed by a blinded assessor for five times (pre-test1, post-test 1, pre-test2, post-test 2, follow up at three month). The outcome measures Fugl-Meyer Assessment-Upper Limb section(FMA-UE),Box and block test(BBT), Maximal voluntary contraction(MVC) of extensor digitorum communis(EDC), Abductor pollicis brevis(APB), Flexor digitorum(FD), Dynanometer, Semmes-Weinstein hand monofilament (SWM), Revision of the Nottingham Sensory Assessment (EmNSA) for hand evaluations, Modified Barthel Index for ADL ability. Collected data will be analyzed with ANOVA test by SPSS version 20.0, and alpha level was set at 0.05. The hypothesis are robot-assisted hand rehabilitation with a Gloreha device has positive effects on sensory, motor, hand function, and ADL ability among patients with stroke.
Study Oversight
Has Oversight DMC:
False
Is a FDA Regulated Drug?:
False
Is a FDA Regulated Device?:
False
Is an Unapproved Device?:
None
Is a PPSD?:
None
Is a US Export?:
None
Is an FDA AA801 Violation?: